EPA - End Profile Analyzer

The EPA - End Profile Analyzer is a Sanitary can end measurement system, which uses laser profiling technology in order to measure the sanitary end.

Incorrect values on the ends can often cause major issues like deadheads, stuck ends, and bad double seams.

The End Profile Analyzer (EPA) replaces "go-no-go" gauges and destructive measurement methods for sanitary ends, which are inaccurate, time consuming and give different results for different operators. With laser profiling technology, the EPA is able to measure all important end specifications using a non-contact optical laser measurement system:

  • End Material Thickness
  • Outside diameter
  • Inside Diameter
  • Chuck Fit Diameter (an actual measurement, not go-no-go!)
  • Curl Width (for the first time, non destructive!)
  • Curl Height
  • External Curl Radius
  • Countersink
  • End flanges
  • Pin Fit
  • First bead
  • New: Chuck wall angle (optional)
  • New: Countersink bottom radius (optional)
epa-optical-unit.jpg
End Profile Analyzer unit
epa-snapshot.gif
End Profile Analyzer - measurement screen

  • Quick measurements (under 1 second!)
  • High accuracy material thickness gauge!
  • High accuracy
  • Automatic measurement ensures repeatability
  • Non-contact, non-destructive measurements
  • Non-destructive measurement of Curl Width
  • Can measure previously difficult to measure values, such as curl width and curl radius!
  • Multilingual! Translations available to most languages!
  • Runs under Windows 2000/XPTM
  • CE certified
  • Prefocused, precalibrated
  • Accurate material Thickness gauge
  • Provides its own reports and also interfaces with SPC systems'
  • New: Chuck wall angle and countersink bottom radius measurements (optional!)

Inner Bead Gauge (Optional)

  • Measures positive and negative inner beads
  • 0.01mm (0.0005") measurement resolution
  • Easily adjustable slider position
epa-title.jpg
epa-optical-unit.jpg

Optical Resolution 10 microns or better
Cover Thickness Resolution 1 micron
Can End diameter range 48mm - 250mm
Max End countersink depth 4.5mm

Inner bead attachment specifications

Bead type Positive and Negative
Resolution 0.01mm (10 microns)
Slider Easily adjustable positioning
Optical Resolution 0.0004" (4 ten thousandths) or better
Cover Thickness Resolution 0.00005" (50 millionths)
Can End diameter range 2"-10"
Max End countersink depth 0.18"

Inner bead attachment specifications

Bead type Positive and Negative
Resolution 0.0005" (5 ten thousandths)
Slider Easily adjustable positioning

end_thickness_gauge.jpg
epa-optical-unit.jpg
epa-snapshot.gif
epa-title.jpg
epa-laser.jpg
EPAreport.jpg